Intelligent Self-priming Peripheral Pump
Product Information
安装
Installation Guide
Valve Installation
Install union gate valves on both inlet/outlet pipelines, positioned 0.2–0.5 meters from the pump for easy maintenance.
Piping Requirements
Use galvanized steel or PPR plastic pipes to minimize pressure loss.
Keep pipelines straight; avoid excessive elbows, reducers, or adapters.
Critical Components
Well intake: Install a one-way foot valve at the pipeline’s lowest point.
Tank supply: Add an overflow shut-off device to prevent continuous operation.
Control Box Setup
Mount the control box facing outward in a dry, shaded area to protect electrical components.
Priming & Startup
Fill the pump with water via the exhaust screw until overflow.
Plug in power → wait 2 seconds for startup → open the farthest faucet to purge air.
After air is expelled, the pump will auto-start/stop (2s delay on, 3s delay off).
Troubleshooting
Pump Fails to Start
Power issue: Verify electrical supply is connected and energized.
Faulty capacitor: Check for swelling/damage; replace if necessary.
Impeller jam: Disconnect power, manually rotate the fan blade.
Control board failure: Short-circuit the pressure switch pins; replace board if no red light.
High pressure: Adjust pressure switch clockwise with a 4mm hex key.
Dry-run protection: Unplug, wait 5 minutes, then reset.
Pump Runs Continuously
Leak detection: Close outlet valve → if pump stops, inspect pipes/appliances for leaks.
Low pressure: Adjust pressure switch counterclockwise until red light turns off.
Flow switch stuck: Clean debris or replace the switch if unresponsive.
Frequent Start-Stop Cycles
Low flow usage:
Replace expandable hoses (e.g., rubber) with rigid pipes.
Ensure faucets are opened >1/3 capacity to stabilize flow.
Adjust pressure switch to raise activation threshold.
Pressure tank issues:
Inflate to 0.5–1 bar via air nozzle; replace tank if water leaks.
System Features
Soft Start/Stop
Starts 2 seconds after power-on; stops 3 seconds after faucet closure.
Dry-Run Protection
Runs for 3 mins → pauses 8 secs → runs 2 mins → stops. Self-resets after 6 hours.
Anti-Freeze & Anti-Jamming
Automatically runs 10 seconds every 12 hours to prevent freezing or sediment buildup.
Leakage Detection
Shuts down after 90 minutes of cycling; yellow light flashes to alert leaks.
Constant Pressure Backup
Restarts if pressure drops below threshold; operates even if flow switch fails.
Power-On Self-Check
Runs 3 seconds after power restoration to reset system.
Note: Always disconnect power before maintenance. Contact the manufacturer for replacement parts if internal components (e.g., circuit board, switches) are damaged.